Metrohm Autolab potentiostat galvanostat electrochemical research workstation with NOVA software

Autolab Potentiostat / Galvanostat for Advanced Electrochemical Research

Modular electrochemical workstations for impedance spectroscopy, batteries, biosensors, corrosion, electrocatalysis, solar cells, nanomaterials and fundamental electrochemistry.

Metrohm Autolab systems can be configured around the research requirement rather than a single fixed instrument. Compact PGSTAT204 systems cover a broad range of routine and advanced electrochemistry, while the PGSTAT302N provides higher current, higher compliance voltage and substantially greater modular expansion for demanding research. Multi Autolab systems extend the platform to independent parallel channels.

Potentiostat & galvanostat control
Electrochemical Impedance Spectroscopy (EIS)
Modular current boosters & accessories
NOVA procedure creation & data analysis
EC-Raman & UV/VIS spectroelectrochemistry
Cells, electrodes, RDE/RRDE & sensor platforms

Electrochemical Research Areas

The same Autolab platform can be configured for very different research programs. For Pakistan, the strongest opportunities are energy materials, sensors and biosensors, corrosion and materials research, electrocatalysis, environmental electrochemistry and solar / photoelectrochemical studies.

Battery and energy storage electrochemical research with potentiostat galvanostat

Batteries, Supercapacitors & Energy Storage

Characterize electrode materials, electrolytes and complete cells using cyclic voltammetry, galvanostatic charge / discharge, impedance spectroscopy, rate studies and long-term electrochemical testing.

Discuss battery research
Electrochemical biosensor and sensor research

Electrochemical Sensors & Biosensors

Develop sensors for biomarkers, pharmaceuticals, heavy metals, food compounds and clinical or environmental targets. Autolab systems can be combined with Metrohm DropSens screen-printed electrodes for miniaturized and disposable sensor research.

Discuss sensor research
Corrosion coatings and materials electrochemical impedance spectroscopy research

Corrosion, Coatings & Materials

Study corrosion mechanisms, protective coatings, passivation, polarization resistance and degradation. EIS is especially powerful for coatings and interfaces where processes occur over multiple time scales.

Discuss corrosion research
Electrocatalysis nanomaterials hydrogen fuel cell electrochemical research

Electrocatalysis, Hydrogen & Fuel Cells

Investigate HER, OER and ORR kinetics, catalyst activity, water splitting, fuel-cell reactions, rotating-electrode experiments and mechanistic electrochemistry for energy-conversion materials.

Discuss electrocatalysis
Solar cell photovoltaic and photoelectrochemical research

Solar Cells & Photoelectrochemistry

Characterize photovoltaic and photoelectrochemical materials, charge-transfer processes, semiconductor interfaces and light-driven electrochemistry, including synchronized optical and electrochemical experiments.

Discuss solar research
Research focus in Pakistan: Current Pakistani Autolab-related research activity is particularly concentrated in electrochemical sensing and biosensors, energy storage, HER / OER / ORR electrocatalysis, fuel-cell research, corrosion and materials, solar / photoelectrochemistry and advanced materials characterization.

Choose the Autolab Around the Research

PGSTAT204 and PGSTAT302N use the same core electrochemical approach and NOVA environment. The main differences are current capability, compliance voltage and the level of modular expansion required. This makes it possible to select the platform around the experiment instead of forcing every laboratory into one configuration.

Metrohm Autolab PGSTAT204 compact modular potentiostat galvanostat
Compact Modular Platform

Autolab PGSTAT204

A compact modular potentiostat / galvanostat suited to general electrochemical research, sensors, corrosion, photovoltaics, batteries and EIS when configured with FRA32M.

  • Compliance voltage: ±20 V
  • Maximum current: ±400 mA
  • Up to 10 A with Booster10A
  • One internal expansion module
  • FRA32M option for EIS
  • NOVA software control
Metrohm Autolab PGSTAT302N advanced modular potentiostat galvanostat
High-Performance Modular Platform

Autolab PGSTAT302N

The preferred platform where higher current, higher compliance voltage, multiple expansion modules, advanced EIS or complex synchronized experiments are required.

  • Compliance voltage: ±30 V
  • Maximum current: ±2 A
  • Up to 20 A with Booster20A
  • Up to 8 optional modules
  • 1 MHz instrument bandwidth
  • Designed for advanced modular research
Metrohm Multi Autolab M204 multichannel potentiostat galvanostat
Parallel Electrochemistry

Multi Autolab / M204

Independent potentiostat / galvanostat channels for parallel electrochemical experiments, high-throughput sensor work, battery studies and research laboratories shared by multiple users.

  • Independent M204 channels
  • Up to 12 channels in one cabinet
  • Different measurements can run simultaneously
  • Optional modules can expand functionality
  • Booster10A available where higher current is needed
  • NOVA software environment
Other configurations: PGSTAT128N, PGSTAT101, Autolab IMP, Multi Autolab variants and specialized packages remain available. CWTC can select the appropriate platform based on current range, voltage, impedance requirement, number of channels, electrodes, accessories and the techniques required by the research group.

Modules, Current Boosters, Cells & Electrodes

Modularity is one of the strongest reasons to choose Autolab. A system can start with the techniques required today and be expanded later as the laboratory moves into impedance spectroscopy, higher-current energy research, multiple working electrodes, quartz-crystal microbalance measurements or automated multi-cell experiments.

Autolab FRA32M electrochemical impedance spectroscopy EIS and NOVA analysis

FRA32M — Electrochemical Impedance Spectroscopy

Potentiostatic and galvanostatic EIS for batteries, coatings, corrosion, fuel cells, sensors and interfaces. FRA32M covers 10 µHz to 32 MHz as a module, with Autolab PGSTAT measurements limited to 1 MHz, and includes impedance fitting and simulation in NOVA.

Autolab current booster for batteries fuel cells and supercapacitors

Current Boosters — 10 A & 20 A

Extend Autolab into higher-current battery, supercapacitor, fuel-cell and large-area electrode research. Booster10A supports PGSTAT204, PGSTAT302N and M204 configurations, while PGSTAT302N can be extended to 20 A with Booster20A.

Autolab electrochemical cells electrodes and accessories

Electrodes, Cells & Research Accessories

Configure the complete measurement system with working, counter and reference electrodes, corrosion and battery cells, RDE / RRDE, Faraday cages, cables, connectors, flow cells and specialized electrochemical accessories matched to the application.

Advanced modules and configurations: BA bipotentiostat · EQCM · MUX · pX1000 · ADC10M · SCAN250 · ECD low-current amplification · ECN · FI20 · high-frequency EIS and other specialist options, depending on the selected Autolab platform.
Metrohm Autolab NOVA electrochemical research software screenshot
NOVA Electrochemical Research Software

Build the Experiment, Control the Autolab, Analyze the Data

NOVA is the software environment for USB-based Autolab instruments including PGSTAT204, PGSTAT302N and Multi Autolab. Researchers can create and modify procedures, follow relevant data in real time, process and plot results, fit impedance data and integrate external devices into synchronized electrochemical experiments.

Cyclic Voltammetry (CV)
Linear Sweep Voltammetry
Chronoamperometry
Chronopotentiometry
EIS & Equivalent-Circuit Fitting
Galvanostatic Charge / Discharge
Potentiodynamic Polarization
Linear Polarization Resistance
Differential Pulse Voltammetry
Square Wave Voltammetry
Open Circuit Potential
RDE / RRDE & Rotating Electrode Work

Go Beyond Conventional Electrochemistry

Autolab can synchronize electrochemical measurements with optical and other analytical techniques, allowing the researcher to connect electrical response with simultaneous structural, chemical or spectroscopic information.

Metrohm Autolab EC Raman spectroelectrochemistry

EC-Raman Spectroelectrochemistry

Synchronize the electrochemical experiment with in-situ Raman spectra to follow structural and chemical changes while potential or current is controlled. Metrohm offers dedicated EC-Raman approaches for battery research, corrosion and electrocatalysis.

Battery materials · Corrosion · Electrocatalysis · Interfaces · Reaction intermediates
Metrohm spectroelectrochemistry UV VIS SPELEC electrochemistry

EC-UV/VIS, Photoelectrochemistry & Easy Hyphenation

Combine electrochemistry with UV/VIS spectroscopy or synchronized external devices to study redox species, intermediates, semiconductor behavior and light-driven processes. Autolab software can also support synchronization with techniques such as XRD, FTIR, SECM, EQCM and DEMS where the experimental setup requires it.

UV/VIS · Photoelectrochemistry · XRD · FTIR · SECM · EQCM · DEMS

Complementary Metrohm Electrochemistry Platforms

Autolab is the modular research platform, but some projects are better served by miniaturized sensor systems, disposable electrodes or a highly integrated next-generation potentiostat. CWTC can combine these technologies within one electrochemistry portfolio.

Metrohm DropSens screen printed electrodes biosensor electrochemistry
Metrohm DropSens

Screen-Printed Electrodes & Miniaturized Electrochemistry

Disposable screen-printed electrodes, compact potentiostats and specialized sensor platforms for electrochemical sensors, biosensors, point-of-care concepts, environmental analysis and high-throughput method development.

The DropSens range also includes impedance-capable compact instruments, spectroelectrochemistry and electrochemiluminescence solutions for research that needs miniaturized cells or integrated optical detection.

Metrohm VIONIC potentiostat galvanostat powered by INTELLO
VIONIC powered by INTELLO

Highly Integrated Next-Generation Electrochemistry

VIONIC combines a wide range of advanced specifications in a single instrument rather than relying on a modular architecture. It offers EIS up to 10 MHz, maximum current of ±6 A, selectable floating, analog scan and Second Sense (S2) for researchers who prefer a highly integrated workstation.

Resources & Downloads

Tell Us What You Are Researching

Share the electrochemical technique, sample or material, expected current and potential range, impedance requirement and research objective. CWTC can help configure the appropriate Autolab system, FRA32M, current booster, cells, electrodes, software and complementary Metrohm electrochemistry products.

Discuss Your Electrochemical Research